Domain I · Maintenance Practices · Sample 1
You have locked the main electrical disconnect for a belt conveyor. The conveyor also has an air cylinder that holds belt tension. What must happen before you reach into the drive area?
A. Begin the work, because the electrical lock already removes the energy that drives the belt.
B. Lock the air supply valve closed, bleed the cylinder, then verify zero energy with a try-start and a gauge check.
C. Hang a danger tag on the air supply valve so others know not to touch it, then begin the work in the drive area.
D. Ask the operator to leave the air on so the belt stays tensioned and does not shift while you work in the drive.
Answer: B
Lockout means every energy source is isolated and stored energy is released or blocked, then zero energy is verified. The air cylinder is a second source and can still move the take-up, so the air valve gets its own lock, the line is bled, and a try-start plus gauge check proves the machine is dead. The main distractor treats the electrical lock as enough, which ignores the stored pneumatic energy. A tag alone does not physically stop anyone from opening the valve.
Domain I · Maintenance Practices · Sample 2
You have just finished an unplanned repair on a cooling-water pump. What should you record when you close the work order in the CMMS?
A. Only the total labor hours, because finance needs those for the cost report and nothing else is ever used afterward.
B. The fault found, likely cause, parts, hours, and as-left condition, recorded against the pump's asset number.
C. Mark the work order complete; the details are better kept in your personal notebook, where you can find them quickly.
D. A one-word note such as 'fixed' so the planner can close the job fast and the backlog count goes down sooner.
Answer: B
Closing a work order with the failure found, cause, parts, hours, and as-left condition builds the equipment history that later troubleshooting, PM changes, and root-cause work depend on. The main distractor keeps that knowledge in a personal notebook, where no one else can use it and the asset history stays empty. 'Fixed' or hours-only entries lose the same information.
Domain II · Preventive and Predictive Maintenance · Sample 3
During a PM on a packaging machine, you find a guard-door interlock switch taped shut so the machine runs with the door open. What should you do?
A. Remove the bypass, test that the interlock stops the machine, and report it on the work order.
B. Replace the tape with a neater zip tie so the switch is held closed more securely.
C. Remove the tape but skip testing the switch, because the switch was working fine when it was taped shut.
D. Leave the tape in place, because production asked for it and the operator knows to keep their hands clear.
Answer: A
A bypassed interlock removes protection against contact with moving parts, so it must be restored, function-tested, and reported so the reason for the bypass is dealt with. The main distractor accepts a bypass based on a production request and operator care, which is how serious injuries happen. Removing tape without testing does not prove the switch works, and a zip tie is still a bypass.
Domain III · Troubleshooting and Analysis · Sample 4
An operator reports that a transfer pump 'is not pumping enough.' What is the best first step?
A. Pull the pump and replace the impeller, because low flow on a pump of this kind usually means the impeller is worn.
B. Check suction and discharge pressure and flow at the pump against normal values to confirm the problem.
C. Order a larger pump, since a reported shortage of flow means the existing pump is undersized for the duty.
D. Close out the request, because the operator gave no numbers to show the flow is low and so the problem is not proven.
Answer: B
Troubleshooting starts by verifying the problem with gauges, flow readings, and observation. Low flow can come from a closed valve, a blocked strainer, a process change, or a pump fault. The main distractor jumps to a repair before confirming the symptom or its cause, which risks a costly and unnecessary tear-down. Closing the request or upsizing the pump also skips verification.
Domain IV · Corrective Maintenance · Sample 5
A repair is complete and the equipment is ready to be returned to service. Which sequence is correct?
A. Restart the equipment first to test the repair, then remove the tools and reinstall the guards once it is shown to be running.
B. Remove tools, refit guards, confirm all clear, each worker removes their own lock, then restart and hand over.
C. Hand the equipment to operations with locks still on, for them to remove when ready.
D. Have one person remove every lock to save time, then reinstall the guards once the restart has confirmed the repair worked.
Answer: B
Return to service puts the machine back in a safe state before energy is restored: tools out, guards on, people clear, each person removes their own lock, then a controlled restart and formal hand-over. The main distractor has one person remove everyone's locks and runs the machine without guards. Restarting before guards are on, or leaving locks for operations to remove, breaks the same rules.